SYSCAD - CAD for metal construction Start  back  next

SYSCAD 2023 (Juli 2023)

About SYSCAD > Revision history > SYSCAD 2023

New commands and options:

 

 

The SYSCAD dialogue boxes have been revised. Whenever possible and useful, it is possible to hide and show parts.

 

 

dialog_normteile_klein

dialog_normteile_gross

Example: Dialogue standard parts library folded in

Example: Dialogue standard parts library folded out

 

 

3D / BIM - output for special insert elements possible, e.g. for sliding doors. This function requires an adjustment of the master data. Please contact us if you have a requirement here.

 

schiebetuer-3d

 

 

 

There is a new button in the glass generator and panel generator objektpfad_waehlen. With this you can select an additional path for fillings (object glasses) and define it in the drawing. This path is preferred for the glass selection.

 
 
kap8_23
 
 

VIS3D / BIM: User-defined parts and edits for 3D profiles from the view can be specified
 

dlg_bim_addeed5

 
 
 

new option in the VIS3D / BIM command: if the check mark is set for SIMPLE_PROFILE_CONTOURS, then no more precise contours (if available) are used for the 3D representation of the profiles, but only the rectangular geometry from the SYSCAD profile data.

 

vis3d-einfache_konturen

 

 

New command kgl_open_dwg_16 to open the DWG file of one (or more) already inserted block.  These blocks are searched for on the hard disk and opened. The directories of the DWG search paths are searched.

 

It is now possible to enter a second measurement (difference to the base) for the Indication of altitude. The second measurement can only be displayed if there is a second text with the EED KGL_HOEKO_MASS_2 in the elevation block. (Example hoekosym5_2.dwg)

 

New commands kgl_syscad_save_16 and kgl_syscad_restore_16 to save the SYSCAD environment and import it again on another PC.

 

New command insert_all1. This allows you to insert blocks/DWGs from directories with subdirectories. The command wblockall1 saves all blocks in this folder again. With the command swap profile contour one can conveniently edit these blocks in the collective drawing.

 

 

 

Modifications:

ARX labelling: new parameters %%o2 %%o3, so that different specifications for the dimensions can be created, e.g. with length / without length.

 

BIM output: Parameters such as: BIM template, path, file name are written to the dictionary of the current drawing and are used with the next command invocation

 

Profile system dialogue: Command: KGL_PROFSYSTEMINFO: the command now no longer switches off or on, but switches on again when it was off, when it was on to x=1, y=1. The command KGL_PROFILSYSTEM_RESET thus becomes unnecessary.

 

ARX labelling: Dialogue: ARX labelling: button <Delete all lines> so that all lines from the default file can be deleted at once

 

ARX labelling: for dynamic blocks, the description from the block definition (if available) is now also used, as for normal blocks, BRICSCAD as of version V22

 

Dynamic blocks can now be glazed, combined, dimensioned, labelled ...

 

In the Sheet and Foil programme, 2 arrows are now displayed with which you can define where the wall thickness is to be offset.

 

With the Transom command, 2 red arrows are now displayed so that the customer knows that it is possible to offset the view widths.
 

Viewports can now be automatically scaled. Parameter %%m

 

With the command: "Measure profile" kgl_profilvermass blocks and rectangles can now also be measured automatically.

 

 

 

Parts library

 

Bohl / Clavu-Fix (new)
 

Fischer / frameanchors / SXRL FUS (new)

Fischer / frameanchors / SXRL FUS R (new)

Fischer / frameanchors / SXRL T (new)

Fischer / frameanchors / SXRL T R (new)

Fischer / steel anchors / FBS II M (new)

Fischer / steel anchors / FBS II P (new)

Fischer / steel anchors / FBS II SK (new)

Fischer / steel anchors / FBS II US (new)

Fischer / steel anchors / FBS II US TX(new)

Fischer / steel anchors / FAZ II clamping width reworked

 

Jordahl / double-notch toothed T-Bolts (new)

Jordahl / hook-head T-Bolts (new)

Jordahl / tee-head Bolts (new)

Jordahl / anchor channels JTA K (new)

Jordahl / anchor channels JTA W (new)

Jordahl / anchor channels JXA W (new)

Jordahl / anchor channels JZA K (new)

Jordahl / toothed T-Bolts (new)

 

Ejot / screws / JT4-FR-2H/6-4,8x22 (new)

Ejot / screws / JZ3 S 6.3 (reworked)

 

Hilti / HUS screw / HUS S (Insertion points corrected)

 

Würth / ASSY 4 / ASSYplus 4 A2 CSMR countersunk milling head RW

Würth / ASSY 4 / ASSY 4 A2 PH full thread

 

HFT / EX-A 6.5 (new)

HFT / EX-BZ 6.3 (new)

HFT / EX-BR (new)

HFT / VS-BR (new)

HFT / screws (new)

 

Spax / flat head screw TG (lengths reworked)
 

standard processing / standardthread inside core diameter reworked

standard processing / threaded drillhole undercut (new)

standard processing / threaded drillhole run-out (new)

standard processing / finethread inside (with and without countersink)

standard processing / standardthread inside (with and without countersink)

standard processing / drillhole fine, medium, rough separated

standard processing / countersink for hexagonscrews fine, medium separated

standard processing / countersink for countersunk screws type A fine, medium separated

standard processing / countersink for countersunk screws type B fine, medium separate

standard processing / countersink for countersunk screws type H,J,K  fine, medium separate

standard processing / countersink for countersunk screws type F (new)

standard processing / countersink for countersunk screws ISO 15065 (new)

 
 

standard screws / DIN 7981 C-TX button head screws type C TX (new)

standard screws / ISO 14585 pan head tapping screws type C (new)

standard screws / ISO 4026 (lengths reworked)

standard screws / ISO 4017 hexagon head screws (new)

standard screws / ISO 4014 / DIN 931 Error in thread lengths corrected

standard screws / ISO 10642 Error with countersunk head corrected / lengths corrected
 

standard diverse / ISO 13918 welding studs (new)

standard diverse / ISO 15977 blind rivet flat head (new)
 

standard washers / DIN 434 square tape washers for U-sections (reworked)
 

angle sections, t-profile, u-profile provided with additional view
 

aluminium u-profile reworked

 

steel / universal beams (UB) (new)

 

 

Fehlerbereinigung

ARX labelling: if no dimension style was set, the one from the SYSCAD variable is taken. If this does not exist, the current one is used (previously crash).

ARX labelling panel: if it was a group, the text default was previously taken from the glass instead of the panel, corrected.

ARX labelling: Aligning the guiding lines of the ARX labelling after double-clicking on the object.

Slide dialogue: If there was a blank line in a user query file, this question was not displayed in the dialogue.

When using the command Convert slide to polyline and back to slide, the user queries were lost.

Creating a new database index in BRICSCAD is now possible again.

KGL_ASVERDECKT: from BRICSCAD V22 onwards, the entities are copied into block for VERDECKT in the same way as in AutoCAD.

SYSCAD does not ask for a dimensioning factor of 0.001 for metre in the height code now again

Glazing with mirrored profiles did not work sometimes

Welding seam bead within a block in the refedit/block editor did not work.

When separating objects / separating foils in SYSCAD, the OFANG was gone.

When stretching profiles in the view at the handle, a 90° end is now automatically created again.

The command KGL_KLONEBLOCK cloned all blocks of a group if the group mode was switched on.

Error in BricsCAD with the command "Apply slide properties", if there was a label on a slide

ARX labelling: with the command: KGL_DELLEADER the labels of concrete, block etc. are no longer removed.

With the command "Delete fill" the section lines are no longer deleted.

In BricsCAD, only user-defined hatchings were displayed in the "Hatchings" dialogue.

With the command "SYSCAD copybase" and "SYSCAD Pasteclip", the elevation notes did not have a reactor.

"View from auxiliary grid" now also takes lines on layer 0 into the selection. In the first run, only auxiliary lines are used. If nothing is found here, all other lines and polylines also work.

In the standard parts library, the block name with the ARX labelling has been capitalised for own drawings.

In the SYSFLY standard parts library toolbox, the Edit button did not work.

Error in BricsCAD corrected. When deleting labelled blocks, an error message no longer appears.

LOGIKAL grid: as of LogiKal version 12 the additional line is no longer generated, in Logikal this has been corrected and it now goes immediately with the grid into the position input

 

 

New setting options in SYSCAD-VARIABLE:

 

SYSCAD Variable / List / 3D-Vis/BIM

- User-defined parts